Multi -square block structure space requirements for compression space [CM] More space/compression space (Compact Machin

Multi -square block structure/machinery

(The core is mainly the center of three -dimensional)

miniature

3x3x3

Small

5X5X5

standard

7X7X7

Large

9x9x9

Giant

11x11x11

maximum

13x13x13

Single nuclear reactor

1x1 (1)

Available

Available

Available

Available

Available

Available

Spatial

Nuclear reactor (full)

(6 nuclear reaction warehouses)

3x3x3-20 (7)

Choose

Spatial

It's difficult to move

Available

Spatial

Available

Spatial

Available

Spatial

Available

Spatial

Available

Spatial

Fluid

(Stelin generates electricity/

Stelin Power Power Generation)

Framework 5x5x5 (125)

Output thermal energy+

Thermal energy conversion power/thermal energy conversion kinetic energy, kinetic energy conversion power+wiring =

Six -sided extension 3 blocks

(Reserve activity space)

Unavailable

Insufficient space

Unavailable

Insufficient space

Unable to do

Unavailable

Insufficient space

(There is no space for thermal power conversion energy)

Unavailable

Insufficient space

(There is no space for wiring on both sides)

Choose

Spatial

There is no room for pumping water

(It is impossible to bury the pump in the water)

You may need to move the entire reactor unit up one square

Available

Spatial

Dragon pile

Core interval: 2 or 3 or 4

Elimage: 7 or 9 or 11

(7x7x7)

(9x9x9)

(11x11x11)

, Energy input and energy output requires one extension 1 grid on both sides

Unavailable

Insufficient space

Unavailable

Insufficient space

Unavailable

Insufficient space

(wiring)

(7x7x7)

Available/unavailable

Spatial

(7x7x7)

Insufficient space

(wiring)-

(9x9x9)

(space)-

(11x11x11)

Option/unavailable

9x9x9: If the core out of control of the reactor, the reactor stabilizer is destroyed due to the core expansion (the interval between the stabilizer and the core is 3)

11x11x11:

Insufficient space

(wiring)

Available

Spatial

(Stabilizer and core interval are 4)

Energy core (the highest level that can be accommodated)

1 level

Level 3

Level 4

Level 5

Level 6

7th level

Note:

1. [Available] indicates that the edge length of the internal space is suitable for placing a multi -block structure and sufficient activity space reserves.

2. [Selected] indicates that although the length of the internal space is suitable for placing a multi -block structure, the space is not enough to play in the player (which can make the player's body) or other problems.

3. [Unavailable] means that the edge of the internal space is not suitable for placing a multi -block structure or although it is suitable for placing a multi -block structure but there is no space with 2 blocks to make it player.no).


1. The characteristics of the core expansion and destruction block of the Shenlong reactor are only 1.10.2.

2. The stabilizer of the multi -block structure of the Shenlong reactor and the core can be 2 blocks, but the MC version can only be 1.7.10.

3. The gap between the core and the stabilizer in the MC version of the MC version 1.10.2 must be above 3 blocks.

4. The size of the energy core is the maximum level 7 in the maximum compression space. The level 8 of the energy core cannot reserve enough space to place the energy core stabilizer.