Multi -square block structure/machinery
(The core is mainly the center of three -dimensional)
miniature
3x3x3
Small
5X5X5
standard
7X7X7
Large
9x9x9
Giant
11x11x11
maximum
13x13x13
Single nuclear reactor
1x1 (1)
Available
Available
Available
Available
Available
Available
Spatial
Nuclear reactor (full)
(6 nuclear reaction warehouses)
3x3x3-20 (7)
Choose
Spatial
It's difficult to move
Available
Spatial
Available
Spatial
Available
Spatial
Available
Spatial
Available
Spatial
Fluid
(Stelin generates electricity/
Stelin Power Power Generation)
Framework 5x5x5 (125)
Output thermal energy+
Thermal energy conversion power/thermal energy conversion kinetic energy, kinetic energy conversion power+wiring =
Six -sided extension 3 blocks
(Reserve activity space)
Unavailable
Insufficient space
Unavailable
Insufficient space
Unable to do
Unavailable
Insufficient space
(There is no space for thermal power conversion energy)
Unavailable
Insufficient space
(There is no space for wiring on both sides)
Choose
Spatial
There is no room for pumping water
(It is impossible to bury the pump in the water)
You may need to move the entire reactor unit up one square
Available
Spatial
Dragon pile
Core interval: 2 or 3 or 4
Elimage: 7 or 9 or 11
(7x7x7)
(9x9x9)
(11x11x11)
, Energy input and energy output requires one extension 1 grid on both sides
Unavailable
Insufficient space
Unavailable
Insufficient space
Unavailable
Insufficient space
(wiring)
(7x7x7)
Available/unavailable
Spatial
(7x7x7)
Insufficient space
(wiring)-
(9x9x9)
(space)-
(11x11x11)
Option/unavailable
9x9x9: If the core out of control of the reactor, the reactor stabilizer is destroyed due to the core expansion (the interval between the stabilizer and the core is 3)
11x11x11:
Insufficient space
(wiring)
Available
Spatial
(Stabilizer and core interval are 4)
Energy core (the highest level that can be accommodated)
1 level
Level 3
Level 4
Level 5
Level 6
7th level
Note:
1. [Available] indicates that the edge length of the internal space is suitable for placing a multi -block structure and sufficient activity space reserves.
2. [Selected] indicates that although the length of the internal space is suitable for placing a multi -block structure, the space is not enough to play in the player (which can make the player's body) or other problems.
3. [Unavailable] means that the edge of the internal space is not suitable for placing a multi -block structure or although it is suitable for placing a multi -block structure but there is no space with 2 blocks to make it player.no).
1. The characteristics of the core expansion and destruction block of the Shenlong reactor are only 1.10.2.
2. The stabilizer of the multi -block structure of the Shenlong reactor and the core can be 2 blocks, but the MC version can only be 1.7.10.
3. The gap between the core and the stabilizer in the MC version of the MC version 1.10.2 must be above 3 blocks.
4. The size of the energy core is the maximum level 7 in the maximum compression space. The level 8 of the energy core cannot reserve enough space to place the energy core stabilizer.