This tutorial is set by the author's setting without permission.
In the MEK 10.4.5 version, the 18*18*18 (maximum size) fission reactor used with 18*18*18 (maximum size) thermal boiler, the position of the partial pressure element is at the maximum rate of the reactor to the maximum rate of burning.A big relationship.
When the partial pressure elements are on the third layer, that is, the first floor with the top, the construction method uses@无 当 当 当 当 当 当 当 当 当 当
However, at this time, no matter how the water inletting of the thermal boiler is increased, the discharge of sodium steam/overheating sodium steam is discharged.The highest fission reactor rate is only 829.48MB/T
As @daichance said, measure with me
However, I think that a polytable reactor only needs to use a thermal boiler, so one fission reactor cannot require two boilers.
So I started the analysis of the relationship between the maximum power of the number of layers and fission reactors in the sorting component in the boiler.
In my test, it was found that when the voltage components were on the fourth layer, it was two layers when the top layer was empty.As shown in the figure
At this time, under the current boiler.The efficiency of the fission reactor can reach 1244.2MB/T as shown in the figure. At this time, the thermal element used in the figure is 256.At this time, I reduced 31 heating elements and then conducted an efficiency test of fission reactors, and found no significant changes.Still 1244.2MB/T.
So I started a lower number of layers of the next step -by -step component.
When the partial pressure elements are at the fifth floor, that is, when the top three layers are the top, the efficiency of the fission reactor as shown in the figure is 1418.5MB/T. At this time, it is very close to the extreme reaction rate of the fission reactor 1435MB/TICK.
So I reducing the number of layers of the partial pressure component again.When the partial pressure elements are on the sixth layer, that is, when the top four layers are the top, as shown in the figure, the limits of the fission reactor can be reached at this time.The reaction rate is 1435MB per tick, as shown in the figure
EssenceStart melting at a higher level, unless there will be more efficient cooling methods than sodium in the future.The temperature of the reactor is 1.19kk.
At this time, the boiling efficiency of the thermal boiler was 2869806MB/T, and the temperature was 23.98kk.You can bring two full -matching turbines.The approximate efficiency is 4/5.Full -time power generation is 40.99mfe*2
As shown in the figure, I use it.Infinite water of lazy kitchen.So.You need to calculate when you use the saturated condenser and the exhaust port.I use the fission reactor corresponding unit configuration- [MEK] MEKANISM -MC Encyclopedia | The largest MINECRAFT Chinese MOD Encyclopedia (MCMOD.CN) is calculated, at least required (1435/R1.6 = 896,R = 14) 897 turbine exhaust holes and 449 saturated condenser.
If you are worried about the results, you can go directly to the largest turbine -based steam turbine (Mek] -MC Encyclopedia of MCMOD Encyclopedia (Mekanism), the largest MCMOD.cnThis is the largest turbine here.
Note that when the thermal boiler is excreted to the turbine.Suppose you take three mouths to the A turbine.B -turbine took four mouths.The A turbine can only get 3/7 steam.B -turbine can get 4/7 steam.When any one of the two turbines has the maximum power generation efficiency, the heat boiler is at this time.There will be problems with cooling and not timely.
So when we make two the same turbine.Our steam bus (important) each with four A turbine valves and B turbine valve is sufficient
In addition, the following is a solution to some common problems.
EG.1 When sodium steam accumulation appears in the thermal boiler
Generally, your pipelines are not set enough.If you put more, he can import the reactor. A fission reactor of 1435MB per TICK needs to be at least 4/5 of the valve as shown in the figure.If you don't worry, you can press the picture below.
In this case, generally input and output are not a problem.Another thing is that the layer where the original pressure is located can be placed with structural glass, and it is like a picture of the boiler.
The EG.2 reactor rate is directly exploded at 1435.
It is recommended to add a little bit from 300,600,900, unless you take a lot of pipelines like me, otherwise you can't keep too much water at once.
If the picture cannot be seen clearly, you can double -click the large.If there is anything unclear, I can send it to the comments, and I will try my best to solve it.