The underestimated array solar [GC] galaxy (GALACTICRAFT) Minecraft Game

This tutorial is set by the author's setting without permission.

In the process of communicating in a communication group, I found that everyone seemed to have some misunderstandings against solar energy, and wrote this tutorial.


The following is the data page in the encyclopedia.

Array Solar:

Solar array is a multi -block structure that can be generated, consisting of solar array controller and array solar monomer module, and the solar array controller and the array solar single module require at least one piece.The aluminum surface of the array solar single module and the array solar controller can form a solar array.

The solar array has the highest power generation efficiency and the best effect on the space station.This is due to the long days of the space station's dimension and no light efficiency attenuation.

The solar array can be centered on the controller and connects the solar energy monomer module of 33*33-2.Avoid material waste.

The power generation efficiency of solar arrays is also affected by the number of modules of light and connection.The solar array cannot cover up the solar energy module when power generation, otherwise it will reduce the efficiency of power generation.

A square block can be shared between multiple solar arrays.

Array Solar Module Module:

Solar panel with built -in wires.

Place this module with the solar array controller on the same level plane to provide electricity.

A solar array controller can connect multiple array solar monomer modules.

The power generation efficiency is the highest on the space station.

Solar array controller:

The solar array controller is the core part of the modular multi -square array solar power system. It is used to control and check the operating status of the solar array, and connect the wire to export energy.

Connect the array solar module to the controller to generate energy.The highest efficiency at the space station and the best effect.

The controller can only control the single module at a unilateral upward direction and cannot obtain energy from a farther module.The efficiency of power generation is also affected by the number of modules that are connected by light and connecting.

According to the above conditions, it is easy to know that a single solar array controller can be at most of it, connecting the solar energy module of 33*33-2 array.


The following is the basic usage of array solar energy.

Prepare at least one solar array controller and array solar single module.(Synthetic form, please go to the corresponding page to query)

All aspects of the array solar monomer module:

Among them, the four sides are aluminum surfaces, which can be connected to other blocks through tightly, and the top and bottom are affected by light.

Four faces of array solar controller:

Among them, there are 3 planes on the side that are aluminum lines, which can be connected to other squares with a tightly attached method.The noodles in the second picture are the transmission surface, which can be connected here to connect the wires and transport electricity outward.

The upper and lower noodles of the solar array controller are decorative surfaces and have no practical effect.

Connect the aluminum surface of the solar array controller and the aluminum surface of the solar monomer module of the solar array to form the simplest solar array.

The solar array is similar to the senior solar panel. It is at the best angle or not, it will operate at the maximum power.

Each array solar monomer module can make the solar array controller generate 6GJ power per second, and can connect more array solar monomer modules to send more electricity.

This is a controller connecting 18 array solar modules and the power generated per second.

As mentioned earlier, each single module can provide 6GJ, but the current power generation is 113GJ, 113/18≈6.3.

Therefore, adding more single modules to the controller can generate more power, and the efficiency is improved at the same time.1+1> 2

However, the number of controllers can be connected with limited number, and only single modules that can be connected within 16 meters in unilaterally.Therefore, if a single solar array controller is used as the center of the array, it can connect up to 33*33-2 array solar modules.

However, the maximum power generation of each controller is 1000GJ, please calculate the amount of each block before building the array to avoid waste materials.

Replace the measurement unit to EU, which is the power generation of the array above.

Each module is added, the power generation will be+1EU/T.

For an IC2 thermal generator, the power generation has reached 10EU/T.

It is not satisfactory to rely on this method to generate electricity alone.


The following is the advanced use of solar array.

As mentioned earlier, the aluminum surface of the module can be connected to other modules or controllers through tightly, and one controller can connect multiple modules.

So, can a module connect multiple controllers?

This plane is connected by 9 modules.

Connect 1 controller with a power generation of 8EU/T.

So, what about another controller next to it?

It can be seen that the second controller can also be generated normally, and the power generation efficiency is the same as the first controller.At this time, the first controller was also generated at the speed just now.

Based on this type, all the modules can be placed all the controllers with bare aluminum lines. At this time, all controllers can be generated normally.

The current power generation speed is 8*3*4 = 96eu/t.Compared with the array of 18 modules, 17EU/T power generation is several times higher.

If you really collect solar dust in Venus, you will know how big this is.At present, when the number of valid modules is unchanged, each with a controller, the power generation+number of modules*1EU is added, and the efficiency is doubled.

Do a test, which is also a array of 25 modules, which connects 1 controller and connect to 20 controllers (all connected) power generation efficiency gaps.

In order to visually display the efficiency of power generation, the EU is used as a power measurement unit. At the same time, in order to avoid the electrical loss of IC2, the heavier aluminum wire of the galaxy is used as a wire.

(Please ignore the constant burning thermal generator)

Connect the controller and MFSU in the icon method to spend a day and observe the power generation of 2 arrays.

The gap is clear at a glance.

The configuration of 25 monomer modules+20 controllers+22 guide lines, consumables are not high. In survival, you can replace the EU heap (non -MOX) of IC2, and do not need to consume nuclear materials.Solar yes